Installation of brake motor

SHANGHAI WANNAN ELECTRIC MOTOR CO.,LTD|2015-06-09 09:05|5664 view

Preparation work before installation: motor out of the box before should check the packaging is intact, the wetting phenomenon, after opening the cover should be carefully remove motor of dust and rust layer, carefully check the transport in the process of deformation and damage, fastener without loosening or shedding, rotation is flexible, whether it meets the requirements of the nameplate data, and 500VMQ table measuring high resistance, insulation resistance should not be less than 1MQ otherwise deal with winding drying processing, but the processing temperature does not exceed the j-20 DEG C.

Motor installation site, and installed base: motor installation site elevation height should be no more than 100 () m; general purpose motor installation site should be dry, clean, around the motor should be well ventilated, and other equipment to leave at regular intervals, in order to check, monitor and cleaning, environmental temperature below 40 DEG C and prevent the intense radiation; installed base to strong, sturdy, rigidity, mounting surface should be smooth, in order to ensure the balanced operation of the motor.

The wiring of the motor: the motor should be properly grounded, junction box below and to the right and housing of the machine base is grounding device, when necessary can also make use of the motor feet or the flange disc fastening bolt grounding, in order to ensure the safe operation of the motor.

Motor and mechanical load connection: the motor can use the coupling, the shaft or the belt and the load machinery, the fan end of the biaxial motor is only allowed to adopt the coupling drive. When the coupling is used, the center line of the motor shaft and the load machine should be coincident, so that the motor will produce strong vibration, the shaft and the abnormal sound.. The deviation of the installation is as follows: 2 the deviation of the pole motor is 0.015mm, and the deviation of 4, 6 and 8 pole motor is 0.04mm. Vertical mounted motor, shaft extension only allows the use of coupling and mechanical load coupling.

Previous:

Next:

Site Map| Service| Privacy| About Us| Contact Us| Order

Copyright © 2024 SHANGHAI WANNAN ELECTRIC MOTOR CO.,LTD wnmotor.net

点击这里给我发消息