Cause and improvement measure of pole winding of DC motor

SHANGHAI WANNAN ELECTRIC MOTOR CO.,LTD|2015-09-10 09:08|6417 view

1 the impact of the electric machine is big and the elasticity of the electric motor is strengthened.

2. A hard link to the line broken, use braided soft wire or cable connection, with leech nail and fastened connection, to reduce operation when line power.

3. Bolt connection at the mouth of the copper strip broken, coil leading out end head and the last turn are fixed at a copper double, to strengthen the mechanical stability.

4 connecting bolts are loose, can be added to the spring or other brake coil, the bolt is not less than M8, the large traction motor can be used for two bolts fastening.

At the film not scrape or surface oxidation of 5 bolts, can be re tighten the bolt and insulated conductive contact surface after sanding.

6 copper breaks lead to bad welding, or to replace the coil to be rewelded.